1.7 Due to the large deviation of the flue gas along the width of the combustion chamber and<br>the temperature difference between the pipe wall and the steam during the rising of the fire,<br>the temperature of the individual superheater pipe wall exceeds the allowable value,<br>so the superheater outlet steam temperature should be kept below The rated temperature is at<br>least 50-60 ° C until the breeze.to this end:<br><br>1.8 Superheater outlet steam temperature shall not exceed 400 °C during the rising period<br><br>1.9The temperature of the superheater pipe wall shall not exceed 500 °C during the rising period.<br><br>1.10If the temperature is too high, open a large air-to-air exhaust valve or adjust the combustion<br>to extend the fire time appropriately.<br><br>2 .Boiler Pressure Raising:<br><br>2.1 According to the design characteristics of boiler and superheater materials in our factory,<br>the regulations stipulate that the time from boiler ignition to working pressure and steaming is<br>generally 6-8 hours, and the cold start boiler is not less than 6 hours, the first ignition boost time longer.<br> The speed during boosting should not be too fast, especially after ignition, the boosting speed<br>should be slower in the initial stage.<br><br>2.2 Time schedule rising pressure: ...